For several years, automobile makers and government agencies have sought ways to improve safety on roadways and effectively manage traffic flow. As wireless communication systems are advancing, the vision of automobiles talking to each other and to roadside units is becoming a reality. These planned automotive wireless communication systems are known as ITS (Intelligent Transportation System). This paper will provide an overview of the current status of the ITS worldwide with a focus on the IEEE 802.11p PHY. Additionally, the paper provides information on test and measurement solutions for devices and components used in ITS.
23-Jan-2014 | AN-No. 1MA152
This whitepaper provides an overview of the WLAN offload in LTE as standardized by 3GPP, as well as the enhancements for Wi-Fi standardized by IEEE and the Wi-Fi Alliance. It also describes access methods in the joint network, treats the security, and describes IP mobility. In addition network discovery and selection are explained.
10-Dec-2012 | AN-No. 1MA214
The LTE technology as specified within 3GPP Release 8 was first commercially deployed by end 2009. Since then the number of commercial networks is strongly increasing around the globe. LTE has become the fastest developing mobile system technology. As other cellular technologies LTE is continuously worked on in terms of improvements. 3GPP groups added technology components into so called releases. Initial enhancements were included in 3GPP Release 9, followed by more significant improvements in 3GPP Release 10, also known as LTE-Advanced. Beyond Release 10 a number of different market terms have been used. However 3GPP reaffirmed that the naming for the technology family and its evolution continues to be covered by the term LTE-Advanced. I.e. LTE-Advanced remains the correct description for specifications defined from Release 10 onwards, including 3GPP Release 12. This white paper summarizes improvements specified in 3GPP Release 11.
09-Jul-2013 | AN-No. 1MA232
The R&S EX-IQ-Box serves as a digital baseband interface between a device under test (DUT) and Rohde & Schwarz generators, analyzers and radio communication testers. The DigIConf software supplied with the device controls up to four R&S EX-IQ-Boxes in a test setup and can thus output IQ data for feeding into a DUT while simultaneously receiving IQ output from a DUT.To work together smoothly, the DUT, the R&S EX-IQ-Box and the R&S test instruments have to be configured properly. The purpose of Application Note 1MA168 is to introduce the right 'initial steps' required to get started successfully.
23-May-2012 | AN-No. 1MA168
1xEvolution ā Data Optimized (1xEV-DO)is a 3GPP2 ācdma2000Ā® High Rate PacketData Air Interfaceā specification. Since its introduction (Release 0), Revisions A and B have brought improvements in the data throughput in both directions and in the overall network capacity. This white paper presents the Revision A and B concepts for 1xEV-DO and explains key features.
23-Sep-2013 | AN-No. 1MA213
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
This white paper describes the basic functionality of antennas. Starting with Hertz's Antenna model followed by a short introduction to the fundamentals of wave propagation, the important general characteristics of an antenna and its associated parameters are explained. A more detailed explanation of the functionality of some selected antenna types concludes this white paper.
04-Nov-2014 | AN-No. 8GE01
Rohde & Schwarz offers unique one-box solutions for reliable testing of air navigation systems such as ILS, VOR and DME.
04-Nov-2010
Complex production workflows in several broadcast, post production or presentation environments not only need a solid storage architecture, but also intelligent project sharing since several teams require access to all data.
18-Nov-2014
- not available -
20-Jul-2001 | AN-No. 7BM25
The present application note describes the possibilities of the Stream Explorer to be remotely controlled by some peripheral program via OLE. Extensions are also discussed, widening the fields of application of such a Client-Server architecture.
31-Mar-1999 | AN-No. 7BM02
Performing a multi-port calibration of a vector network analyzer (VNA) is straight forward by using either a calibration unit with the corresponding numbers of ports or single calibration standards. This paper shows how to perform a n-port multi-port calibration by using calibration unit with a lower number of ports than available of the vector network analyzer.
06-Feb-2013 | AN-No. 1EZ70
This application note shows how to determine the quality of a video streamed by an LTE mobile with R&S®CMW500 Radio Communication Tester and R&S®VTE Video Analyzer. The R&S®CMWrun Test Software with CMW-KT051 General Purpose and CMW-KT105 AV Difference Analysis option allows the user to easily automate these tests.
08-Sep-2014 | AN-No. 1MA253
Rohde & Schwarz signal generators can be connected in various ways to system controllers (typically PCs) and external PC peripherals. Although most of these connection operations are also explained in the instrument manuals, it is not always easy to maintain an overview. Operating manuals commonly focus on explaining a dedicated feature of a single instrument. This application note examines a range of typical user tasks and how to solve them with the different instruments.
26-Apr-2013 | AN-No. 1GP72
Are there really power peaks that are 20 dB above the average value? Yes, there are. Ever since the introduction of digital transmission technology, it has been necessary to deal with such orders of magnitude. RF power components must be suitably dimensioned to handle the expected voltage peaks and avoid breaking down. If we can determine the crest factor, i.e. the ratio of the peak value to the average or RMS value, with sufficient accuracy (even though it can only be assessed statistically), then we will have solved the question of dimensioning power components. This Application Note is intended to help with this problem by providing some useful insights including basic formulas, some statistical background and a practical look at the limiting factors when it comes to dealing with real transmitter systems.
22-Jan-2011 | AN-No. 7TS02
While RF communication signal distortions in nonlinear transmission paths have been predicted theoretically and studied experimentally for various signals, it is interesting to examine a wideband nonlinear system reaction to a wideband 3G signal and a narrowband 2G signal. Research and testing have demonstrated that, while most vital signal parameters remain within the limits specified by applicable standards even if composite signal power approaches specified maximum power, a relatively high level of spurious emissions caused by cross- and intermodulation can result. To avoid degrading both existing and new systems, this and other signal quality issues must be considered when designing and deploying multitechnology systems.
03-Nov-2006 | AN-No. 1MA110
The duration of a measurement in multi evaluation list mode is sensitive to the test setup. This document describes various methods to achieve optimized performance for such measurements. The availability of the methods depends on the CMW500 version.
17-Jul-2012 | AN-No. 1CM100
The MHL standard specifies the transmission of high-definition audio and video data on five individual lines, as well as the exchange of bidirectional control information and the supply of power from the sink to the source. Over 200 million portable CE devices - such as mobile phones, tablet PCs and cameras - already use this interface to present content onto larger screens. To ensure functionality and interoperability, every new MHL-capable device must, before entering the market, undergo thorough tests at an authorized test center (ATC) in line with the compliance test specification (CTS) issued by the MHL Consortium. This application note provides an overview of the MHL technology and also describes the Rohde & Schwarz compliance test solution for the system part of the current MHL2.0 standard version.
14-May-2013 | AN-No. 7BM83
This application note describes a software application that can be utilized in conjunction with Rohde&Schwarz Signal- and Spectrum Analyzers and Signal Source Analyzers to capture and analyze transient signals. The software application takes advantage of the instrumentās IQ memory buffer of up to 705 Msamples to capture and analyze IQ signals in the time domain and / or frequency domain. This is useful for measuring lock time, analyzing radar pulses, finding spurious transients, and other measurements similar in nature to these. This application can be used with R&SĀ®Signal Source Analyzer FSUP and R&SĀ®Signal and Spectrum Analyzers FSQ, FSU, FSG, FSV.
16-Feb-2009 | AN-No. 1MA141
R&S®NRPView has been replaced by software Power Viewer Plus, which is provided together with software R&S®NRP Toolkit.Please use the link given below to download R&S®NRP Toolkit.
18-Dec-2008 | AN-No. 1MA77
Getting started with IQ Streaming Application
The intention of this Application Note is to provide an overview of all necessary tasks for getting along with successful IQ Streaming.The necessary technical requirements are described as well as the streaming parameters of the IQ data stream.The general operation and basic setup of the MSR4 is described in the user manual and is not part of this document.
28-Mar-2023 | AN-No. 1179.7104.02
This application note provides information about spectral measurements with noise correction. The basic requirements and the limiting factors of a spectrum analyzer are explained. Dynamic range improvements by means of a noise correction is presented. Measurement examples show the improved performance of TOI measurements with noise correction.
25-Oct-2012 | AN-No. 1EF76
The measurement of error vector magnitude (EVM) is relative ā but what is the reference?
02-Mar-2020
Rare faults and intermittent signals are difficult to capture. The R&S®RTO Oscilloscope supports the acquisition and the detailed signal analysis of these signals by using the history mode. The history mode allows the user to look back to previous acquisitions and apply the wide set of analysis functions of the RTO. Furthermore it stores the accurate recoding time of the waveforms for subsequent analysis.
03-Jun-2013 | AN-No. 1TD02
This application note describes how to configure the signal source analyzer R&S FSUP for highest dynamic range phase noise measurement in the microwave frequency range up to 50 GHz. It compares performance in terms of phase noise sensitivity using an additional internal down converter versus an external down converter or a frequency divider. Both methods are described and differences are shown.
18-Feb-2009 | AN-No. 1EF68
Especially with test receivers not comprising a built-in disk drive (ESHS10, ESVS10, ESVD, ESVB and ESPC) it is necessary to store instrument settings before a firmware update or before changing the battery of the static memory to be able to restore the settings later on. Frequently it is desirable to exchange settings or comprehensive data like transducer sets between receivers, or receivers have to be set up to suit different applications.
18-Jan-2002 | AN-No. 1EE20
Due to todayās worldwide highly competitive communications market, achieving shorter product design cycles, quicker response to customer requests and high-volume product runs at low costs is vital for manufacturers of wireless devices and components. These requirements inevitably lead to demands for improving the throughput of Automated Test Equipment (ATE) by increasing its speed. This application note describes in detail how the special features of the R&SĀ® SMATE200A can be used to optimize speed and throughput in an automated test environment.
17-Apr-2007 | AN-No. 1GP63
It is frequently desired to process the results stored on the floppy on a PC, eg for the generation of customer-specific test reports by means of a word processing system. To enable processing on an external PC, the binary data usually need conversion into an ASCII format. This is possible by means of the ESXS2ASC.EXE program. The program is available free of charge from your Rohde & Schwarz representative.