Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1138 Results
The LTE technology as specified within 3GPP Release 8 was first commercially deployed by end 2009. Since then the number of operators implementing the technology is strongly increasing around the globe. LTE has become the fastest developing mobile system technology. The same way GSM and WCDMA have been enhanced with additional features over time, LTE is continuously worked on. Initial enhancements have been included in 3GPP Release 9 and are described in this white paper.
19-Dec-2011 | AN-No. 1MA191
3GPP Release 9 Technical Specification (TS) 37.141 covers multistandard radio base station conformance testing. Multistandard radio includes four standards of mobile communications: GSM, WCDMA, TD-SCDMA, and LTE. This application note introduces the concept of multistandard radio base stations as well as solutions for transmitter and receiver tests based on Rohde & Schwarz signal generators and Rohde & Schwarz signal and spectrum analyzers.
06-Jul-2012 | AN-No. 1MA198
This document describes the typical measurements performed on mixers and how they can be implemented on the ZVA Vector Network Analyzer with the ZVA-K4 Frequency Conversion option. The document describes the concept and setups required to perform Conversion Loss, Isolation, Intermodulation and Reflection measurements.
06-May-2009 | AN-No. 1EZ58
This Application Note focuses on measurement of harmonics using modern spectrum analyzers. It highlights the source of harmonics before focusing on their measurement using a spectrum analyzer. The Application Note also explains the benefits of the R&S FSWās high pass filter option for harmonic measurements.
02-Mar-2012 | AN-No. 1EF78
This application note describes how to integrate R&S®ZVA/ZVB/ZVT vector network analyzers with AWR's electronic design automation (EDA) software. Measured data can be exported using the AWR® TestWave⢠tool via GPIB/LAN and verified with simulated data. Basic filter design is simplified with the AWR® iFilter⢠filter synthesis wizard, an optimization tool that can be introduced to correlate measured data with simulated data.
01-Jun-2010 | AN-No. 1MA163
This application note presents the Jitter analysis capabilities of the R&S®RTO for digital signals. It demonstrates the basic operation with an application example, and shows the associated jitter analysis.
29-Aug-2013 | AN-No. 1TD03
This application note gives a short summary on the Allan variance as a measure of frequency stability and an example on how to calculate it, with measurement results from R&S spectrum analyzers. A software program to sample data from R&S spectrum analyzers and calculate the Allan variance is available.
11-Feb-2009 | AN-No. 1EF69
A typical application for signal generators and spectrum analyzers is measuring nonlinearities of RF amplifiers. This application note discusses the basics of nonlinearities and describes the nonlinearity measurement using the R&S Value Instruments RF Signal Generator R&S®SMC100A and Spectrum Analyzer R&S®FSC.
20-May-2014 | AN-No. 1MA71
With IT and OT environments converging, security concerns relating to devices and applications deployed in networked test labs, especially in T&M environments, are growing. The demands on IT security here are manifold and include, for example, remote access to in-house infrastructures, equipment rented from external providers, and the continuous deployment of devices across different time zones.
18-Oct-2022
The measurement speed for spurious signal measurements is mainly defined by the spectrum analyzer sweep speed. With traditional swept spectrum analyzers and tight spurious limits the measurement can easily take hours or even a full day. This application note describes the differences in sweep speed between swept spectrum analyzers and modern spectrum analyzers with a wide-band FFT process, and how this improves the measurement speed for general spurious measurement.
10-Jul-2012 | AN-No. 1EF80
Automating measurement setups is advantageous for multiple reasons. It saves time in case of repeated measurements and in hazardous environments, instruments can be operated from a distance. The measurements are repeatable because they are always performed with a defined procedure, leading to higher test confidence.But in remote control applications, users often perceive synchronization and binary transfers as challenging. Therefore, this application note focuses on binary transfer of data to and from the instrument and shows code example to demonstrate the ease of use.
31-Mar-2022 | AN-No. 1SL381
This application notes introduces the Multi-Standard Radio Analyzer function of the R&S®FSW and shows how it performs the measurement on multi-standard radio transmitters. It reveals interactions caused by the coexistence of signals of different cellular standards and localizes the root cause. With an example of a base station signal consisting of three radio access technologies (GSM/WCDMA/LTE FDD) it shows how easy interactions can be found. The R&S®FSW is the ideal tool for trouble shooting tasks with its combination of a large bandwidth and the versatile Multi-Standard Radio Analyzer in one measurement instrument.
17-Jul-2012 | AN-No. 1EF83
This application note describes the techniques to measure the dielectric properties of materials using a vector network analyzer. It also shows methods for converting the s-parameters to dielectric properties.
23-May-2012 | AN-No. RAC-0607-0019
In environments such as mobile use as well as in service shops and education, spectrum analyzers with dedicated built-in pulsed-signal analysis features are often not available. This paper describes the smartphone app Pulsed RF Calculator that aids in finding the right choice of spectrum analyzer settings to calculate the so-called pulse desensitization for manual compensation of pulsed signal amplitudes. Automatic compensation and many other features necessary for in-depth pulsed signal analysis require the use of dedicated functionalities and are outside the scope of this app.
24-Sep-2015 | AN-No. 1MA240
The scope of the subject āradarā has expanded in the recent years in terms of its technical evolution and spreading of applications. This application note along with its corresponding white paper 1MA207 show how to use the R&S radar product portfolio to tackle test and measurement tasks in modern radar technology. Target groups are students who want to become familiar with radar issues as well as radar professionals who want to solve certain test and measurement tasks.
10-Aug-2012 | AN-No. 1MA127
The high-definition multimedia interface (HDMIā¢) is used to transmit audio and video data. HDMI has become the standard for a variety of consumer electronic products, such as Blu-ray⢠players, A/V receivers, set-top box, TV monitors and digital video/ still cameras. The HDMI interface measurements needed for these products require specialized T&M equipment. This equipment is not only needed for certification, but is also used for a variety of tests during development, for quality assurance and for end-of-line production testing. The R&SĀ®VTC, R&SĀ®VTE and R&SĀ®VTS video testers from Rohde & Schwarz make it possible to test A/V interfaces such as HDMI easily, reliably and cost efficiently. This application note focuses on functional testing and debugging of HDMI interfaces using the R&SĀ®VTC/VTE/VTS. It explains how these instruments can be used to assess the HDCP implementation, the ARC or the CEC functionality.
04-Jun-2014 | AN-No. 7BM85
This application note describes how the transmitter landscape of a DVB-T2 single-frequency network (SFN) can be simulated in multiple input single output (MISO) mode in order to test the compatibility and performance of receiver modules. Neither an external T2-MI gateway nor a GPS receiver is required - just an R&S®BTC equipped with two RF paths. Alternatively, one R&S®SFU coupled with one or more R&S®SFU, R&S®SFE, R&S®SFE100 or R&S®SFC can also be used. R&S®ETL or R&S®ETC are suggested to fine-tune the synchronization between the generated RF signals.
03-Feb-2014 | AN-No. 7BM80
A major US East Coast broadcast network was looking for a solution that would enable them to orchestrate multiple business units to handle the increased demand to deliver content with a very fast turnaround.
18-Nov-2014
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T / DVB-H transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
13-May-2013 | AN-No. 7BM101
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required ATSC transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commis-sioning and preventive maintenance.
13-May-2013 | AN-No. 7BM102
Version 1.3.1 of the DVB-T2 standard ETSI 302 755 introduced the T2-Lite profile to ease the implementation of mobile TV services. This was achieved by minimizing the complexity of the required receiver and allowing side-by-side integration into existing conventional (T2-Base) DVB-T2 channels. For the purposes of testing the compatibility and performance of receiver modules, this application note describes how this type of composite T2-Base/T2-Lite RF signal can be simulated using one R&S®BTC or alternatively two instruments from the family of broadcast signal generators comprised of the R&S®SFU, R&S®SFE, R&S®SFE100 and R&S®SFC. Only one corresponding multiple profile T2-MI stream is required, either in the form of a file or via an external gateway.
03-Feb-2014 | AN-No. 7BM81
TeleZüri, Switzerlandās most successful regional TV station, has switched from tape-based operations to file-based workflows. At the same time, TeleZüri was introducing HD as standard resolution in its workflows.
18-Nov-2014
The terrestrial television standard DVB T2 is gaining in significance as a result of the growing scarcity of available frequencies. New systems are being tested in many countries around the world. Other countries have already completed the introductory phase for DVB T2. Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers or even disrupt adjacent channels.A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T2 transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.The measurements described here satisfy many country-specific and customer-specific test specifications. Users need only set the limit values accordingly.
24-Jul-2014 | AN-No. 7BM106
In this application note, a UHD 4K end-to-end solution utilizing products from Rohde & Schwarz is described in detail from the point at which 4K content is captured until its delivery to households via a DVB-T2 SFN network.
29-Aug-2014 | AN-No. 7BM90
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to legacy adapter assemblies supporting USB3.1 Gen1, and USB2.0. Based on 5 Gbps signaling per lane with vector network analyzers from Rohde & Schwarz.
18-Jan-2024 | AN-No. 1SL407
A future-proof API to enable and streamline customized and automated workflows with Rohde & Schwarz DVS software applications.
18-Nov-2014
I/Q waveform files contain the digital complex sample values of a radio signal. They can be synthetically computer-calculated for generating precisely defined contents, or they can represent the recording of a received live signal. The structure of these files has never been standardized, which is why so many different formats are in use today. R&S®IQ Converter and R&S®IQ Stream Extractor are programs that quickly and conveniently convert the contents of I/Q waveform files of nearly any structure into the I/Q format used by the R&S®BTC, R&S®CLG, R&S®SLG, R&S®SFU, R&S®SFE and R&S®SFE100 signal generators. This makes it possible for the signal generators to use their integrated ARB function to generate precise RF signals from nearly any I/Q waveform file.
03-Feb-2014 | AN-No. 7BM79
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many listeners. A single instrument, the R&S®ETL TV analyzer, performs all required DAB transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
24-Jul-2013 | AN-No. 7BM104